Without doubt the most compact leak detector on the market, operating up to 100 bar.
SUBMISSIONS:
Leak testing of catheters, cooling parts, oil radiators, high pressure pipes and lines, valves, hydraulic brakes and other high pressure parts.
Key features:
Differential pressure drop leakage measurement
1 measuring range (ΔP): 5000 Pa
32 programmes
Electronic pressure regulator 4 MPa
Mechanical pressure regulator 8 MPa
Measurement characteristics of sensors:
| Sensor type | Domain | Accuracy* | Resolution |
| 5000Pa | 0-5000Pa | ±(displayed value 2,5 %-a + 10 Pa) | 1Pa |
Options:
Technology: Differential pressure drop leakage measurement
The differential pressure drop measurement method is particularly important for high pressure measurements, as it allows the measurement of the leakage rate with Pa resolution, independent of the gauge pressure.
The F520 HP has the same pneumatic design principle as the other differentials, but of course the components are sized to withstand the high pressure:

The test component (3) and the reference component (5) are loaded to the same pressure, and the differential sensor (4) measures the pressure variation between the test component (5) and the reference component (3) during the measurement cycle. In some applications, the reference component may be replaced by a sealing cap, in which case the reference volume is provided by the internal volume of the ATEQ (1,5 cm3).
If you have any questions about our services or would simply like to learn more about how we can assist you, please do not hesitate to contact us. We strive to respond to all enquiries as quickly as possible.